eCHEM Reference cell
eCHEM Ref OD11
- Reference cell to test your eCHEM Setup: Cycler, Probes + interface
- Allows the testing of DC (CC-CV cycling, CV, etc.) and EIS capabilities
- 3-Electrode or a 2-Electrode configuration
- Compatible with all probes capable of holding PCC-SHORT-OD11
- Contact us for reference cells in different dimensions or customized to your needs
BioLogic SP-150e
BioLogic SP-150e potentiostat
- The SP–150e is the only ampere capable electrochemical workstation to boast high-current capability (800 A with boosters), three EIS quality indicators (THD, NSD, NSR) for Electrochemical Impedance Spectroscopy validation and Ethernet compatibility for improved group-working.
- Voltage
-- Control voltage: Different measurement ranges available between [-20; to +20] V (customizable); up to 60 V with FlexP0060/FlexP0160
-- Voltage resolution: 5 µV to 305 µV
-- Compliance: ±10 V adjustable between [-20; to +20] V (standard)
-- Accuracy: < 0.1 % Full Scale Range (20 mV)
- Current
-- Current ranges: 1 A to 10 µA (6 ranges). Automatic current range available.
-- Maximum current: ±1 A; up to 800 A with four FlexP0012
-- Current resolution: 0.004 % of the range (min 760 pA)
-- Accuracy: < 0.1 % Full Scale Range (min 20 nA)
- Advanced
-- Up to 2 channels
-- Connection 2,3,4,5 terminal lead
-- Best acquisition time: 20 µs with EC-Lab® developer package
-- Stability control mode (7 bandwidths)
-- Control software: EC-Lab® (incl. free updates) and EC-Lab® developer package
-- Ethernet or USB 2.0 connection to PC/laptop
Option: Electrochemical Impedance Spectroscopy (EIS)
- Frequency range: 1 MHz down to 10 µHz
- EIS quality indicators
Options for SP-50e and SP-150e
- Additional cell cable 3 m
- Additional cell cable 5 m
- Additional cell cable 10 m
BioLogic SP-50e
BioLogic SP-50e potentiostat
- Cost-effective, portable, robust, single channel, general purpose potentiostat perfect for both general electrochemistry research needs as well as teaching.
- Voltage
-- Control voltage: ±10 V. Different measurement ranges available.
-- Voltage resolution: 5 µV to 305 µV
-- Compliance: ±10 V
-- Accuracy: < 0.1 % Full Scale Range (20 mV)
- Current
-- Current ranges: ± 10 µA to ± 1 A (6 ranges). Automatic current range available.
-- Maximum current: ±1 A
-- Current resolution: 0.004 % of the range (min 0.760 nA)
-- Accuracy: < 0.1 % Full Scale Range (min 20 nA)
- Advanced
-- Connection 2,3,4,5 terminal lead
-- Best acquisition time: 20 µs with EC-Lab® developer package
-- Stability control mode (7 bandwidths)
-- Control software: EC-Lab® (incl. free updates) and EC-Lab® developer package
-- Ethernet or USB 2.0 connection to PC/laptop
Option: Electrochemical Impedance Spectroscopy (EIS)
- Frequency range: 1 MHz down to 10 µHz
- EIS quality indicators
Options for SP-50e and SP-150e
- Additional cell cable 3 m
- Additional cell cable 5 m
- Additional cell cable 10 m
BioLogic SP-200
BioLogic SP-200 potentiostat (with EIS)
- Single channel – transportable potentiostat
- The perfect electrochemical workstation for corrosion with the 76 fA accuracy ultra-low current option
- Voltage
-- Compliance: ±12 V
-- Control voltage: Customizable ranges from ±10 V down to ±30 mV; Up to [0; 48] V with HCV-3048
-- Voltage resolution: From 1 µV on 60 mV range
-- Accuracy < ± 1 mV ± 0.03 % of setting
- Current
-- Current ranges: 1 A to 10 nA (standard); down to 1 pA (Ultra Low Current – option!)
-- Maximum current: ±500 mA (standard); up to 120 A with four HCV-3048
-- Current resolution: 0.004 % of the range. 760 fA (standard); down to 76 aA (Ultra Low Current – option!)
-- Accuracy < ± 0.1 % of range ± 0.03 % of setting
-- Note, ultra low current is an option (additional module) and not included with this configuration.
- Electrochemical Impedance Spectroscopy (EIS)
-- Frequency range:
-- 11 MHz (3%, 3°) down to 10 µHz; 3 MHz (1%, 1°)
-- EIS quality indicators
- Advanced
-- Connection 2,3,4,5 terminal lead
-- Best acquisition time: 12 µs with EC-Lab Express; 1 µs with ARG option
-- Floating mode – relevant if your cell is grounded via the in situ NMR probe/experiment
-- Analog filtering
-- Calibration board included
-- Full stability control mode (9 bandwidths)